Resources
Displaying 91 - 100 of 102
Last updated: 17 Jul 2023
Part D GZ13 Otago.pdf
… 4.1 to 4.5 below, these form the base assumptions for this report: ▪ Studholme is supplied from Waitaki in Winter, with … before the voltage and thermal issues identified in this report, particularly for planned outages of 220 kV circuits … ceases operation in 2025, this will be the only remaining transmission constraint binding in this scenario for both …
Last updated: 30 Jan 2025
GL-EA-959 Asset Capability Information Guideline.pdf
… of a new or modified connection: ▪ before the completion of planning for the construction (Planning ACS) ▪ at, or … New Zealand’s electricity system, along with a summary of transmission charges. ▪ GL-EA-953 Connection Study Guide for … commissioning documentation and test results. Commissioning reports should confirm prior performance assessments and the …
Last updated: 15 Apr 2025
SO Industry Forum 15 April 2025
… unit commitment or wind generation if a large generation or transmission asset fails. Market update Energy: National … commitment or wind generation should a major generation or transmission asset not be available/trip during May. Firm … finalising our draft Security of Supply Assessment (SOSA) report in preparation for consultation. Next SO Forum will …
Last updated: 17 Oct 2023
UG-SD-1071 SO Register Asset Owner User Guide.pdf
… that this non-compliance may have on the System Operator planning to comply, and comply, with their Principal … onto New Zealand’s electricity system, plus a summary of transmission charges. Connection Study Guide for Connecting … Estimate acceptance Engineering assessment Assessment Report review Report approval Draft decision Consultation …
Last updated: 07 Jul 2025
GL-EA-010 Generator Testing Requirements.pdf
… 69 Appendix A. Sample Test Report Structure … Generation Commissioning Process Feasibility Initiation Planning Delivery Commissioning Closeout … without incident with both the generator and the islanded transmission network energised ▪ manage frequency and … and any local auxiliaries ▪ assess the ability to liven transmission circuits following a partial or total shutdown …
Last updated: 25 Sep 2024
Standard Ancillary Services Procurment Contract 2024.pdf
… Department or authorised agency ceases to compile and report figures for the Consumers Price Index (all groups), … operator engaged in the co-ordination of an integrated transmission network under the same or similar circumstances … error in such date and no automated message indicating a transmission error). 14.2 Not a Business Day: If any such …
Last updated: 14 Feb 2025
PR-OC-204 Security Constraints Process.pdf
… issue. © 2025 Transpower New Zealand Limited Operations Planning Engineer In the context of this document, an … Factor Operations Planning are notified by … Change to transmission network or operating policy ▪ Commissioning or … ▪ Operations Planning Engineer from event log and system reports Document Status: Issued Doc File Name:PR-OC-204 …
Last updated: 14 Jan 2025
Transient Rotor Angle Stability Study
… or cascading failure. Besides our study findings, this report recommends further assessment, discussions with asset … type of faults can occur between the three conductors of a transmission line or buses at a substation. This is a low … power system. https://www.transpower.co.nz/system-operator/planning-future/system-security-forecast TRANSPOWER NEW …
Last updated: 08 Dec 2022
GL-OC-984 Dispatch Schedule Load Input guideline.pdf
… good. If communications to an individual meter fails, the reported quality is bad. This impacts whether the market … is almost equal to the island load, plus losses across the transmission network. Given a reasonable loss estimate9, and … GXP supply capacity; 11 The combination of generation and transmission resources needed to delivery the Required Load. …
Last updated: 28 Nov 2024
SPD_Model_Formulation_v14.0_mh5
… ALL RIGHTS RESERVED The information contained in the report is protected by copyright vested in Transpower New Zealand Limited (“Transpower”). The report is supplied in confidence to you solely for your … 10 3.5 HVDC Transmission System … 12 3.6 AC Transmission System …