Resources
Displaying 591 - 600 of 1207
Last updated: 06 Dec 2022
8. ELECTRA submission to Transpower's RCP4 Consultation - 3 November 2022.pdf
… 'Electrifying the economy is not just about adding transmission capacity, it is also about making sure the … our approach for embedding innovation and efficiency in our planning? If not, please let us know why. On page 40 of its … Page 9 of 13 Question Comment Q16 How should Transpower report on our progress on delivering resilience programmes? …
Last updated: 26 Jun 2024
DTA 10 April 2024
… 10 April 2024 Schedule 12.6 cl 1.1 Default transmission agreement template Default Transmission … 47 35. DEFINITIONS 47 36. SERVICE STANDARDS 48 37. REPORTING 49 Electricity Industry Participation Code 2010 … on the Customer to provide information to facilitate system planning, as set out in clause 12.54 of the Code); and (c) …
DTA template including modifications to align with TPM changes
(PDF 551.26 KB)
Last updated: 09 Jul 2020
2019 POCP SO Response.pdf
… 2019 Review System Operator Response to 2019 POCP Review Report Transpower New Zealand Limited July 2020 Version Date … Senior Engineer 01/07/2020 Reviewed By: Angela Houston, Planning & Project Support Manager 01/07/2020 IMPORTANT … in capability due to equipment constraints, but not due to transmission constraints. The TAG also agreed that: ▪ It …
2019 POCP SO Response.pdf
(PDF 238.87 KB)
Last updated: 15 May 2023
GL-EA-765 Grid Asset Test Requirements.pdf
… 20 12 Transmission Line Parameter Tests … 34 Sample Report Headings … industry/asset-owner-requirements/asset-test-planning. 3.1.4 Submission of information When reviewing the … IEEE Guide for the Functional Specification of Transmission Static Synchronous Compensator (STATCOM) …
GL-EA-765 Grid Asset Test Requirements.pdf
(PDF 1.07 MB)
Last updated: 16 Apr 2020
International Power System Event Review - Lessons Learnt for New Zealand - UK LFDD Event_Final.pdf
… https://www.transpower.co.nz/ TRANSPOWER REPORT: Review of UK event 9 August 2019 TABLE OF CONTENTS … Event sequence: • Eaton Socon-Wymondley Main 400 kV AC transmission circuit ▪ initially tripped by lightning • … system. 16 The UK SQSS specifies the minimum standard for planning and operating of the national electricity system, …
Last updated: 10 Jan 2024
TP Environmental Performance Handbook - 01 July'21.pdf
… owner and operator of the National Grid – the high voltage transmission network made up of lines and substations … are embedded into practices and processes. � Auditing and reporting on environmental performance. � Requiring all … of most sections of this Handbook. 2. SUPERVISORY, PLANNING AND MANAGEMENT personnel will require a thorough …
TP Environmental Performance Handbook - 01 July'21.pdf
(PDF 7.54 MB)
Last updated: 02 Nov 2022
September 2020.pdf
… TP.HSW 01.13b Health, safety and wellbeing performance report 10/13/2020 H&S Performance 1/1 Health, Safety & … point rules; and a helicopter flying under a 220kV transmission line while carrying out line surveying works. … Project will be Re-planned to commence in July. • Planning for July recommencement. • Identifying stakeholders …
September 2020.pdf
(PDF 9.1 MB)
Last updated: 13 Sep 2022
WUNIVM investigation update May 2018_0.pdf
… Determination GSC Grid Support Contract, used for non-transmission solutions GZ Grid zone MCP Major Capex Proposal … anspower.co.nz/upper-north-island-generation-decommissioning-report-and-appendices and … N-G-1 security standard and the prudent forecast we use for planning purposes. The need grows from then at about 50 MW …
WUNIVM investigation update May 2018_0.pdf
(PDF 1.11 MB)
Last updated: 08 May 2018
WUNIVM investigation update May 2018.pdf
… Determination GSC Grid Support Contract, used for non-transmission solutions GZ Grid zone MCP Major Capex Proposal … anspower.co.nz/upper-north-island-generation-decommissioning-report-and-appendices and … N-G-1 security standard and the prudent forecast we use for planning purposes. The need grows from then at about 50 MW …
WUNIVM investigation update May 2018.pdf
(PDF 1.11 MB)
Last updated: 23 Oct 2020
TI-DP-xx Draft CUWLP 10 minute off load time process-Meridian (for website).pdf
… load times to 10 minutes during the CYD CML TWZ tactical transmission upgrade (TTU) outages and Clutha and Upper … Contingency definitions have been built to monitor and report on the impacts of a CYD CML TWZ circuit tripping when … when running to 10 minute off load times during a planned transmission outage ▪ Planned transmission outages resulting …