Companion guide, consenting and conceptual design drawings, and additional resources for developing a 220 kV Single Circuit standard substation design.
Companion Guide - 220kV Single Circuit Substation Design - DG 25.05
- Consenting Drawings
Document ID Document Title TP211528_1 Standard Concept (Customer Connection) 220/33 kV Switchyard Consent Example (33 kV Air Insulated Switchgear) TP211529_1 Standard Concept (Customer Connection) 220/33 kV Switchyard Consent Example (33 kV Indoor Switchgear)
- Conceptual Design Drawings
Document ID Document Title TP211530_1 220kV Standard GIP 2DD-HST Connection General Arrangement Double Circuit Line TP211530_2 220kV Standard GIP Pole Connection General Arrangement Single Circuit Line TP211530_3 220kV Standard GIP 2DD-HST Connection General Arrangement Single Circuit Line TP211527_1 Standard Concept (Customer Connection) 220/33 kV Single Line Diagram (Design) (33 kV Air Insulated Switchgear) TP211527_2 Standard Concept (Customer Connection) 220/33 kV Switchyard Index and Information (33 kV Air Insulated Switchgear) TP211527_3 Standard Concept (Customer Connection) 220/33 kV Switchyard General Arrangement (33 kV Air Insulated Switchgear) TP211527_4 Standard Concept (Customer Connection) 220/33 kV Switchyard General Arrangement (33 kV Indoor Switchgear) TP211527_5 Standard Concept (Customer Connection) 220/33 kV Switchyard Setout Plan (33 kV Air Insulated Switchgear) TP211527_6 Standard Concept (Customer Connection) 220/33 kV Switchyard Elevations (33 kV Air Insulated Switchgear) TP211527_7 Standard Concept (Customer Connection) 220/33 kV Switchyard Lightning Shielding (33 kV Air Insulated Switchgear) TP212582_1 Standard Design 220/33 kV Relay & Instrument Diagram (Design) Line Protection TP212582_2 Standard Design 220/33 kV Relay & Instrument Diagram (Design) Bus Coupler Protection TP212582_3 Standard Design 220/33 kV Relay & Instrument Diagram (Design) for Transformer T1 TP212582_4 Standard Design 220/33 kV Relay & Instrument Diagram (Design) Transformer T2 Protection TP212582_5 Standard Design 220/33 kV Relay & Instrument Diagram (Design) Transformer T3 Protection
- Additional Resources
Document Type Document Title File Lines 220kV - Single Circuit Conceptual Design Summary Report PDF Lines 220 kV - Single Circuit Conceptual Design Summary Report PLS-CADD Weather Case and Load Criteria Generator Excel File Appendix A NZ-6485 GIP Standard GIP-PLS-CADD WC & LC Generator Master Site Specific Wind Speeds Excel File Appendix B NZ-6485 GIP Standard GIP Site Specific Wind Speeds 220kV Standard GIP Connection General Arrangement Drawings PDF Appendix C 220kV Standard GIP Connection General Arrangement Drawings Standard 220 kV CC – Designer’s Log PDF Standard 220 kV Customer Connection (CC) - Designer's Log Material List Appendix D Materials List 220kV Single Circuit Bentley 3D Models Model Access Form - External Registration Form for Users of Bentley Apps
GIP 220kV Single Circuit 2DD-HSTC JOCKEY ARM - 00 DEGREE MOT 120