Companion guide, consenting and conceptual design drawings, and additional resources for developing a 220 kV Double Circuit standard substation design.
Companion Guide - 220kV Double Circuit Substation Design - DG 25.07
- Consenting Drawings
Document ID Document Title TP212584_1 Standard Concept Customer Connection Double Circuit Local 220/33 kV Switchyard Consent Example (33 kV Air Insulated Switchgear) TP212585_1 Standard Concept Customer Connection Double Circuit Local 220/33 kV Switchyard Consent Example (33 kV Indoor Switchgear) TP212587_1 Standard Concept Customer Connection Double Circuit Remote 220/33 kV Switchyard Consent Example (33 kV Air Insulated Switchgear) TP212588_1 Standard Concept Customer Connection Double Circuit Remote 220/33 kV Switchyard Consent Example (33 kV Indoor Switchgear)
- Conceptual Drawings
Document ID Document Title TP212398_1 220kV DC Standard GIP Inline Substation – Pole Terminal Structures General Arrangement Double Circuit Connection TP212398_2 220kV DC Standard GIP Inline Substation – Tower Terminal Structures General Arrangement Double Circuit Connection TP212399_2 220kV DC Standard GIP Remote Substation – Tower Configuration General Arrangement Double Circuit Loop In-Out Connection TP212583_1 Standard Concept Customer Connection Double Circuit Local 220/33 kV Single Line Diagram (Design) (33 kV Air Insulated Switchgear) TP212583_2 Standard Concept Customer Connection Double Circuit Local 220/33 kV Switchyard Index and Information (33 kV Air Insulated Switchgear) TP212583_3 Standard Concept Customer Connection Double Circuit Local 220/33 kV Switchyard General Arrangement (33 kV Air Insulated Switchgear) TP212583_4 Standard Concept Customer Connection Double Circuit Local 220/33 kV Switchyard General Arrangement (33 kV Indoor Switchgear) TP212583_5 Standard Concept Customer Connection Double Circuit Local 220/33 kV Switchyard Setout Plan (33 kV Air Insulated Switchgear) TP212583_6 Standard Concept Customer Connection Double Circuit Local 220/33 kV Switchyard Elevations (33 kV Air Insulated Switchgear) TP212583_7 Standard Concept Customer Connection Double Circuit Local 220/33 kV Switchyard Lightning Shielding (33 kV Air Insulated Switchgear) TP212586_1 Standard Concept Customer Connection Double Circuit Remote 220/33 kV Single Line Diagram (Design) (33 kV Air Insulated Switchgear) TP212586_2 Standard Concept Customer Connection Double Circuit Remote 220/33 kV Switchyard Index and Information (33 kV Air Insulated Switchgear) TP212586_3 Standard Concept Customer Connection Double Circuit Remote 220/33 kV Switchyard General Arrangement (33 kV Air Insulated Switchgear) TP212586_4 Standard Concept Customer Connection Double Circuit Remote 220/33 kV Switchyard General Arrangement (33 kV Indoor Switchgear) TP212586_5 Standard Concept Customer Connection Double Circuit Remote 220/33 kV Switchyard Setout Plan (33 kV Air Insulated Switchgear) TP212586_6 Standard Concept Customer Connection Double Circuit Remote 220/33 kV Switchyard Elevations (33 kV Air Insulated Switchgear) TP212586_7 Standard Concept Customer Connection Double Circuit Remote 220/33 kV Switchyard Lightning Shielding (33 kV Air Insulated Switchgear) TP212582_1 Standard Design 220/33 kV Relay & Instrument Diagram (Design) Line Protection TP212582_2 Standard Design 220/33 kV Relay & Instrument Diagram (Design) Bus Coupler Protection TP212582_3 Standard Design 220/33 kV Relay & Instrument Diagram (Design) for Transformer 1 TP212582_4 Standard Design 220/33 kV Relay & Instrument Diagram (Design) Transformer T2 Protection TP212582_5 Standard Design 220/33 kV Relay & Instrument Diagram (Design) Transformer T3 Protection
- Additional Resources
Document Type Document Title File Lines DC 220KV – Connection Inline Substation Report PDF Lines Double Circuit 220KV – Inline Substation Conceptual Design Summary Report Lines DC 220KV – Connection Remote Substation Report PDF Lines Double Circuit 220KV – Remote Substation Conceptual Design Summary Report Std 220 kV CC DC – Designer’s Log PDF Standard 220 kV Customer Connection (CC) Double Circuit - Designer's Log Material List Appendix D Material List 220kV Double Circuit Bentley 3D Models Model Access Form - External Registration Form for Users of Bentley Apps
Std 220 kV CC – local lightning
Std 220 kV CC – remote lightning
GIP_220kV Double Circuit 2DD-HST MOT 120
GIP_220kV Double Circuit 2DD-HSTC JOCKEY ARM - 45 DEGREE MOT 120